Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Type of study
Language
Year range
1.
Rev. colomb. cardiol ; 26(5): 296-299, sep.-oct. 2019. graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1092941

ABSTRACT

Resumen Se describe el caso de una mujer de 68 años que presentaba insuficiencia tricuspídea severa con ventrículo derecho dilatado, función sistólica levemente deprimida y ventrículo izquierdo no dilatado con fracción de eyección del 47%. Se intervino mediante cirugía realizándose una sustitución valvular tricúspide por prótesis mecánica ATS n( 33 e implante de electrodo de marcapasos epicárdico definitivo. En el postoperatorio inmediato presentó ascenso persistente del segmento ST en la cara inferior. Se implantó balón de contrapulsación intraaórtico y en el ecocardiograma urgente se observó disfunción ventricular global con aquinesia de la cara inferior. Se realizó coronariografía urgente observándose una imagen de angulación y deformidad a nivel distal de la arteria coronaria derecha no presente en la coronariografía prequirúrgica que sugería tracción externa del vaso, probablemente en relación con la sutura quirúrgica. Se intervino en forma percutánea implantándose stent farmacoactivo con lo cual se recuperó el flujo distal y se normalizó el segmento ST. La proximidad del anillo tricúspide a estructuras anatómicas como la arteria coronaria derecha hace posible su lesión durante la cirugía. El daño iatrogénico de la arteria coronaria derecha requiere diagnóstico y tratamiento precoz. Por ello esta complicación se debe incluir en el diagnóstico diferencial de disfunción ventricular derecha tras cirugía cardiaca.


Abstract The case is presented on a 68 year-old woman with severe tricuspid insufficiency. She also had a dilated right ventricle, a slightly depressed systolic function, and an undilated left ventricle with an ejection fraction of 47%. We treated her surgically, the tricuspid valve replacement was carried out with an ATS Nº 33 mechanical prosthesis and implanted a permanent epicardial pacemaker lead. In the immediate post operative period, she presented a persistent ST segment elevation on the inferior wall. An intra-aortic balloon pump was implanted; the urgent echocardiogram showed a global ventricular dysfunction with akinesia of the inferior wall. An urgent coronary angiography was performed, with an image of angulation and deformity being observed at distal level of the right coronary artery that was not present in the pre-surgical coronary angiography, which suggested an external traction of the vessela probably associated with a surgical suture. Percutaneous intervention was carried out, with a drug-eluting stent being implanted. It was percutaneously treated by implanting a drug-eluting stent restoring distal blood flow and normalizing the ST segment. The proximity of the tricuspid ring to anatomical structures like the right coronary artery means that it could be damaged during surgery. The iatrogenic damage to the right coronary artery requires an early diagnosis and treatment. For this reason, this complication must be included in the differential diagnosis of right ventricular dysfunction after cardiac surgery.


Subject(s)
Humans , Female , Aged , Congenital Abnormalities , Heart Valve Prosthesis , Intraoperative Complications , Prostheses and Implants , Thoracic Surgery , Ventricular Dysfunction , Coronary Vessels
SELECTION OF CITATIONS
SEARCH DETAIL